Troubleshooting e-cpos interfaces, Symptom, Solution – H3C Technologies H3C SR8800 User Manual

Page 62

Advertising
background image

55

Troubleshooting E-CPOS interfaces

Symptom

An E-CPOS interface is physically up, the channelized POS interfaces on it are up, but its link layer is

down.

Solution

•

The physical parameter settings (such as clock source and scrambling) on the E-CPOS interface do
not match those on the remote E-CPOS interface.

•

The link layer protocol of the POS channel does match that of the remote POS channel.

•

The bandwidth of POS interfaces channelized from the local E-CPOS interface is not the same as
that of POS interfaces channelized from the remote E-CPOS interface.

•

POS interfaces channelized from the local E-CPOS interface are not the same as POS interfaces
channelized from the remote E-CPOS interface in POS interface number.

•

PPP authentication fails on the virtual POS interface. PPP authentication maybe fails due to incorrect

PPP authentication parameters.

You can use the display interface pos interface-number command to display the multiplexing path and

PPP link negotiation information of the specified POS interface.
An interface may be in one of the following four states:

•

Posinterface-number current state: DOWN ( Administratively ). Line protocol current state: DOWN,

indicating that the interface is administratively shut down.

•

Posinterface-number current state: DOWN. Line protocol current state: DOWN, indicating that the

interface is not enabled or has not gone up on the physical layer

•

Posinterface-number current state: UP. Line protocol current state: UP, indicating that the interface
has passed LCP negotiation.

•

Posinterface-number current state: UP. Line protocol current state: DOWN, indicating that the
interface has been activated but has not passed LCP negotiation.