Troubleshooting poe, Analysis, Solution – H3C Technologies H3C MSR 50 User Manual

Page 182: Failure to apply a poe profile to a poe interface

Advertising
background image

169

Troubleshooting PoE

Failure to set the priority of a PoE interface to critical

Analysis

•

The guaranteed remaining power of the PSE is lower than the maximum power of the PoE interface.

•

The priority of the PoE interface is already set.

Solution

•

In the first case, either increase the maximum PSE power or reduce the maximum power of the PoE
interface if the guaranteed remaining power of the PSE cannot be modified.

•

In the second case, remove the priority that is already configured.

Failure to apply a PoE profile to a PoE interface

Analysis

•

Some configurations in the PoE profile are already configured.

•

Some configurations in the PoE profile do not meet the configuration requirements of the PoE
interface.

•

Another PoE profile is already applied to the PoE interface.

Solution

•

In the first case, remove the original configurations.

•

In the second case, modify the configurations in the PoE profile.

•

In the third case, remove the application of the undesired PoE profile from the PoE interface.