73

Step Command

Remarks

3.

Create an entry in the
alarm table or private

alarm table.

•

Create an entry in the alarm table:
rmon alarm entry-number alarm-variable

sampling-interval { absolute | delta }

rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2

[ owner text ]

•

Create an entry in the private alarm table:

rmon prialarm entry-number prialarm-formula

prialarm-des sampling-interval { absolute |

changeratio | delta } rising-threshold
threshold-value1 event-entry1
falling-threshold

threshold-value2 event-entry2 entrytype { forever |

cycle cycle-period } [ owner text ]

Use at least one
command.

Table 8 Restrictions on RMON configuration

Entry

Parameters to be compared

Maximum number of

entries

Event

Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or

log-trapcommunity)

60

Alarm

Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta), rising

threshold (threshold-value1) and falling threshold
(threshold-value2)

60

Prialarm

Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or

delta), rising threshold (threshold-value1) and falling

threshold (threshold-value2)

50

Displaying and maintaining RMON

Task Command

Remarks

Display RMON statistics.

display rmon statistics [ interface-type
interface-number
] [ | { begin | exclude |

include } regular-expression ]

Available in any view.

Display the RMON history
control entry and history

sampling information.

display rmon history [ interface-type
interface-number
] [ | { begin | exclude |

include } regular-expression ]

Available in any view.

Display RMON alarm
configuration.

display rmon alarm [ entry-number ] [ | { begin |
exclude | include } regular-expression ]

Available in any view.

Display RMON private alarm
configuration.

display rmon prialarm [ entry-number ] [ |
{ begin | exclude | include } regular-expression ] Available in any view.

Display RMON event
configuration.

display rmon event [ entry-number ] [ | { begin |
exclude | include } regular-expression ]

Available in any view.

Advertising