8937/8937D Instruction Manual

Configuration

8937D Module

The Standards Selections page for the 8937D (

Figure 13 on page 23

) pro-

vides a common reporting of signal loss control for both DAs and two sets
of separate controls for standard selection.

Click the

Apply

button to enter all values.

•

The Report Loss of Signal control is common to both DAs. A loss of
signal will be reported if either one or both DAs lose the input signal.

Set the input presence reporting to

Yes

or

No

for both DA 1 and DA 2.

Disabling this control will gray out the corresponding Input signal on
the Status web page graphic shown in

Figure 10 on page 19

.

For DA 1:

•

Set the Mode control for DA 1 to

Auto

(input bit rate standard detected

by module),

Manual

(input bit rate standard selected manually), or

Bypass

(input bypasses reclocking circuitry).

•

The Input Signal field will report the status of the DA 1 input signal.

•

When Auto or Bypass mode is selected, the currently detected bit rate
detected by the module will be displayed in the Current Bit Rate field.

•

When

Manual

mode is selected, a Standard Selection pulldown will

appear similar to the one shown in the DA 2 illustration in

Figure 13 on

page 23

. Select the bit rate from the Standard Selection pulldown

(

143 Mb

,

177 Mb

,

270 Mb

, or

360 Mb

) as desired. The currently selected

manual rate will be shown next to the pulldown.

For DA 2:

•

Set the Mode 2 control for DA 2 to

Auto

(input bit rate standard detected

by module),

Manual

(input bit rate standard selected manually), or

Bypass

(input bypasses reclocking circuitry).

•

The Input Signal 2 field will report the status of the DA 2 input signal.

•

When Auto or Bypass mode is selected, the currently detected bit rate
detected by the module will be displayed in the Current Bit Rate 2 field.

•

When

Manual

mode is selected, a Standard Selection 2 pulldown will

appear similar to the one shown in

Figure 13 on page 23

. Select the bit

rate from the Standard Selection 2 pulldown (

143 Mb

,

177 Mb

,

270 Mb

, or

360 Mb

) as desired. The currently selected manual rate will be shown

next to the pulldown.