8937/8937D Instruction Manual

7

8937 and 8937D Reclocking
EQ SNMP DAs

Introduction

The 8937 module is a 1 x 8 looping input, auto-reclocking, auto-cable equal-
izing DA with SNMP monitoring capability. The module is suited for
medium to long distance signal distribution.

The 8937D (dual) module provides two separate SDI distribution ampli-
fiers on a single card. It also has auto-reclocking, auto-cable equalizing with
SNMP monitoring capability. The module is ideal for environments where
compact and high density capability is required such as mobile trucks.

The 8937 and 8937D feature:

•

Jumper selectable bypass/reclock mode with auto bypass,

•

Auto detection and front panel indication of all SMPTE 259M signal
data rates,

•

Auto format detection (525/625),

•

Auto cable equalization for up to 300 meters of cable with front panel
EQ warning,

•

Suitable for SMPTE 310M, SMPTE 259M, DVB-ASI, SDI 270 Mb/s and
other 800 mV data ranging from 4 Mb/s to 360 Mb/s,

•

Signal presence indication with selectable SNMP trap generation, and

•

Remote health monitoring interface.

This manual covers installation, configuration, and operation for both the
8937 and 8937D modules.