Installation, Frame capacity, Module placement in the gecko 8900 frame – Grass Valley 8937 v.1.0.0 User Manual

Page 8

Advertising
background image

8

8937/8937D Instruction Manual

Installation

Installation

Installation of a module is a process of:

1.

Placing the module in a video frame slot, and

2.

Cabling and terminating signal ports.

The module can be plugged in and removed from a Gecko 8900 video
frame with power on. When power is applied to the module, LED indica-
tors reflect the initialization process (see

Power Up

on page 14

).

Frame Capacity

The 8937 and 8937D module can be installed in all Gecko 8900 video frames
but with varying maximum quantities determined by frame cooling
capacity.

Table 1

provides the power capacity, cooling capacity, and

maximum module count for each frame type.

Note

Module capacity figures assume no other modules are in the frame.

Module Placement in the Gecko 8900 Frame

There are ten cell locations in the video frame to accommodate modules.
These are the left ten locations. Refer to

Figure 1

.

The two cells on the right are allocated for the power supplies. For addi-
tional information concerning the Power Supply module, refer to the 8900
Power Supply manual.

The third cell from the right is allocated for the Frame Monitor or 8900NET
Network Interface module. These modules provide health monitoring and
control options.

Table 1. Video Frame Power Capacity

Capacity Calculated

8900TX Frame

8900TF Frame

8900TFN Frame

Power (W)

100

100

100

Recommended Module Cooling (W)

30

100

100

8937 Modules

10

10

10

8937D Modules

10

10

10

Advertising