Service, Power-up diagnostic failure, Troubleshooting – Grass Valley 8964DEC v.1.1.0 User Manual

Page 65: Refer to

Advertising
background image

8964DEC/-FS — Instruction Manual

65

Service

Service

The 8964DEC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

Power-Up Diagnostic Failure

If the module has not passed self-diagnostics, do not attempt to trouble-
shoot. Return the unit to Grass Valley (see

Module Repair

below).

Troubleshooting

If your module is not operating correctly, proceed as follows:

•

Check frame and module power and signal present LEDs.

•

Verify power at the voltage testpoints (see

Figure 33

) and check Fuse F1

if no voltage is detected.

•

Check for presence and quality of input signals.

•

Verify that source equipment is operating correctly.

•

Check cable connections.

•

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 7 on page 18

for the location of PWR LED and

Table 2 on

page 19

for proper LED indications.

Figure 33. 8964DEC Fuse and Voltage Testpoints Locations

8208_08

r1

Voltage Testpoints

J1

+5V

–5V

+3.3V

+1.5V

Fuse: 2 A Slow

125 V

F1