8964ENC/-FS — Instruction Manual

Service

Service

The 8964ENC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

•

Check frame and module power and signal present LEDs.

•

Verify power at the voltage testpoints (see

Figure 32

) and check Fuse if

no voltage is detected.

•

Check for presence and quality of input signals.

•

Verify that source equipment is operating correctly.

•

Check cable connections.

•

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 7

for the location of PWR LED and

Table 2 on page 19

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the Contacting Grass Valley

on page 4

at the front of this document

for the Grass Valley Customer Service Information number.

Figure 32. 8964ENC Fuse and Voltage Testpoint Locations

8209_09

r2

Voltage Testpoints

J1

+5V

–5V

+3.3V

+1.5V

Fuse: 2 A 125 V

F2