2 ventilation, 3 power requirements – Grass Valley Branding Panel User Manual
Page 82

RCP-BR: Guide to Installation and Operation
Page 74
Miranda Technologies Inc.
5.2
Ventilation
The RCP-BR unit is forced-air cooled. Air is drawn into the unit through holes at
the rear of the unit. Air is exhausted through holes both at the rear and along one
side of the unit.
Because air is drawn in from and exhausted back out into the rear, it is important
that air-space at the rear of the unit is well ventilated.
Note : It is essential that unit ventilation holes remain clear of obstruction.
Note : It is essential that the air-space at the rear of the unit is well-ventilated.
5.3
Power requirements
The RCP-BR unit is DC-powered via the supplied PSU AC power adapter. AC
mains voltage 90V-264VAC 47Hz-63Hz.
Power consumption:
RCP-BR unit
40W DC max.
RCP-BR unit & AC adapter
50W max.