Connecting Densité and Imaging Series Housing Frames
Densité frames can be connected over the network through an Ethernet router, or directly to your PC or
laptop via a crossover cable. Imaging frames (Symphonie and Quartet 2) are connected to your PC or
laptop using either the IC-USB device, or an RS-232-to-RS-422 converter.
Connecting multiple Densité Series frames through a router, and up to 4 Imaging Series frames via IC-USB
Connecting a single Densité Series frame without a router
Adding Densité Communicator Services
To add a Densité Communicator service:
1. Open iControl Solo, and double-click DensiteManager in the logical navigator view.
See also:
For more information about the IC-USB device, see
"Installing IC-USB", on page 23
Customer-supplied PC or laptop that has
iControl Solo
Up to 4 daisy-chained Imaging frames
Up to 100 Densité cards