Timing analyzer – Grass Valley Kayenne XL Package Installation v.7.0.4 User Manual
Page 90

90
Kayenne XL Package — Installation and Service Manual
Section 4 — System Cabling
Timing Analyzer
The Timing menu on switcher systems (accessed via Install – E-Box – Tining)
has a Timing Analyzer pane, which can help when timing the system.
Figure 61. Install - E-Box - Timing Pane
This analyzer reports the timing position of a selected source relative to the
Kayak HD internal sync generator. The source is selected with AUX Bus 1.
The relative position of that source is reported in lines and μs. Positive
values indicate the source is later in time than the internal sync generator,
and negative values indicate the source is earlier.
Kayak HD/Kayenne XL systems have an autotiming window. Sources that
fall within that window will be properly timed throughout the system,
even if the signal is cascaded through multiple MEs.
The Genlock Phase soft knobs adjust the timing of the switcher system rela-
tive to the incoming reference.