Fuse replacement, Maintenance – Grass Valley NV5256 v.1.8 User Manual

Page 45

Advertising
background image

NV5256 Machine Control Router • User’s Guide

37

5. Maintenance

Fuse Replacement

Figure 5-1. EM0374 Battery Replacement

Fuse Replacement

The I/O cards and the control cards include non-serviceable, self-resetting thermal fuses. These
fuses open in the event of a serious overload, preventing major damage. They will self-reset if
allowed to cool.
A replaceable AC fuse cartridge is used on the PS6100 power supply modules. The correct fuse is
15A (1.25

″ × 0.25″ fast-blow).

The correct fuse for the older PS6000 power supply is given in this table:

If a fuse fails, locate the cause of the trouble rather than simply replacing the fuse blindly. Although
fuses that have been in service for years may fail due to cumulative stress, a fuse normally fails for
a significant reason. Please contact Miranda for assistance if a fault cannot be isolated.

Low-battery Indicators

Coin Cells

Status Lights

Note

Reinstall battery with positive terminal (+) facing away from the main circuit
board. (That is to your left if the control card is in installed in the frame.) Insert-
ing the battery backwards may result in an explosion.

90–130VAC

8.0A, 5×20

mm, slow-blow fuse

180–250VAC

6.3A, 5×20

mm, slow-blow fuse

Advertising