Introduction, Overview, Section 1 — introduction – Grass Valley Trinix Back-Up Power Supplies Jan 13 2012 User Manual
Page 29

29
Trinix Installation and Service Manual
Overview
Section
1
Introduction
Overview
The instructions are for the original Trinix DV-33128, DV-33256 and DV-
33512 routing switchers.
For Installation instructions for the newer NXT or Asymmetrical frames,
see Installation for NXT and Newer Frames
. For more information
about these frames see the Trinix Installation and Service manual.
The TRX-PS-BU series of products, sometimes referred to as “tertiary”
power supplies, are designed to supplement the Trinix DV-33128, DV-33256
and DV-33512 internal power supplies to provide increased backup protec-
tion. Two packages are available:
•
TRX-PS-BU1200 - 1 ea. 1200 watt module mounted in a 1 RU frame
•
TRX-PS-BU2400 - 2 ea. 1200 watt modules mounted in a 1 RU frame
These packages can be used in various combinations with Trinix DV-33128,
DV-33256, and DV-33512 routers. This flexibility is shown in
next page.
The power supplies are bussed together so that the power load is shared at
all times. If one power supply fails, the remaining power supplies on that
bus will continue to provide power. The failed power supply should be
replaced as soon as possible.