Maintenance, Diagnostic display code definitions, Diagnostic codes – Polaris 2016 600 Rush PRO-S User Manual

Page 104

Advertising
background image

102

MAINTENANCE

Diagnostic Display Code Definitions

Open Load: There is a break in the wires that lead to the item listed in
the chart (injector, fuel pump, etc.), or the item has failed.

Short-to-Ground: The wire is shorted to ground between the electronic
control unit and the item listed in the chart.

Shorted Load: The wires leading to the item listed in the chart are
shorted together, or the item has shorted internally.

Short-to-Battery: The wire leading from the item listed in the chart to
the electronic control unit is shorted to a wire at battery voltage.

Diagnostic Codes

Component

Condition

SPN

FMI

Throttle Position Sensor

Voltage Too High

51

3

Voltage Too Low

4

Abnormal Rate of Change

10

Vehicle Speed Sensor

Data Erratic, Intermittent or Missing

84

2

Intake Air Temperature Sensor

Voltage Too High

105

3

Voltage Too Low

4

Barometric Pressure Sensor

Voltage Too High

108

3

Voltage Too Low

4

Engine Temperature Sensor

Voltage Too High

110

3

Voltage Too Low

4

Temperature Too High

16

Engine Overheat Shutdown

0

Temperature Above Normal Range

15

Alternator Power Supply
Potential (DC Chassis Voltage)

Voltage Too High

167

3

Voltage Too Low

4

Exhaust Temperature Sensor

Voltage Too High

173

3

Voltage Too Low

4

ECU Memory

Checksum/CRC Error

628

13

Injector 1 (MAG

Driver Circuit Open/Grounded

651

5

Driver Circuit Short to B+

3

Injector 2 (PTO)

Driver Circuit Open/Grounded

652

5

Driver Circuit Short to B+

3

Knock Sensor 1

Voltage Too Low

731

4

Ignition Coil Primary Driver 1
(MAG)

Driver Circuit Open/Grounded

1268

5

Fuel Pump Driver Circuit

Driver Circuit Open/Grounded

1347

5

Advertising