Shortening the probe, Shortening the probe -15, Rosemount 3300 series – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 39: Reference manual

Advertising
background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

3-15

Rosemount 3300 Series

Shortening the Probe

Flexible Twin/Single Lead

Rigid Single Lead

1. Cut the Single Lead probe to the desired length.

2. Update the transmitter configuration to the new probe length, see “Probe

Length“ on page 4-9.

NOTE!
The PTFE covered probes must not be cut in field.

1. Mark off the required probe length. Add at

least 1.6 inch/40 mm to the required probe
length to be inserted into the weight.

2. Loosen the Allen screws.

3. Slide the weight upwards as much as

needed in order to cut the probe.

4. Cut the probe. If necessary, remove a

spacer to make room for the weight.

5. Slide the weight down to the required

cable length.

6. Tighten the screws.

7. Update the transmitter configuration to the

new probe length, see “Probe Length“ on
page 4-9.

If the weight was removed from the cables
when cutting, make sure that at least 1.6
inch/40 mm of the cable is inserted when the
weight is replaced.

Allen
screws

Minimum:
1.6 inch/
40 mm

Spacer

Cut

FLEX TWI

N

SHO

R

T3