13 touch trigger probes – HEIDENHAIN TNC 370D User Manual
Page 31

3–28
TNC 370 D
Mounting and Electrical Installation
July 02
3.7.13 Touch Trigger Probes
Any of the following touch trigger probes for workpiece measurement can be connected.
TS
220
Touch trigger probe with cable connection: for digitizing, workpiece setup and
workpiece measurement during machining
TS
630
Touch trigger probe with infrared transmission: for workpiece setup and workpiece
measurement during machining
X12 Touch Probe Input for Workpiece Measurement
Logic unit
D-sub terminal
(female) 15-pin
Assignment
1 0
V
3 Ready
4 Start
5
+15 V ± 10% (maximum 100mA)
6
+ 5 V ± 5% (maximum 100mA)
7
Battery warning
8
0 V (U
N
)
9 Trigger
signal
10
Trigger signal
1
2, 11 to 15
Do not use
Housing External
shield
1)
Stylus at rest means logic level High