7 coor dinat e t ransf or mation cy cles – HEIDENHAIN TNC 320 (340 55x-03) User Manual
Page 339

HEIDENHAIN TNC 320
339
8.7 Coor
dinat
e
T
ransf
or
mation Cy
cles
Configuring the datum table
If you do not wish to define a datum for an active axis, press the DEL
key. Then the TNC clears the numerical value from the corresponding
input field.
To leave a datum table
Select a different type of file in file management and choose the
desired file.
Status displays
In the additional status display, the TNC shows the values of the active
datum shift. (See “Coordinate transformation” on page 40)
Copy the present value
Insert the copied value
Add the entered number of lines (reference points)
to the end of the table
Function
Soft key
After you have changed a value in a datum table, you must
save the change with the ENT key. Otherwise the change
may not be included during program run.