1 measur ing w o rk piece misalignment – HEIDENHAIN TNC 320 (340 55x-03) Touch Probe Cycles User Manual
Page 43
Advertising

HEIDENHAIN TNC 320
43
3.1 Measur
ing W
o
rk
piece Misalignment
Characteristics common to all touch probe
cycles for measuring workpiece misalignment
For Cycles 400, 401 and 402 you can define through parameter Q307
Default setting for basic rotation
whether the measurement
result is to be corrected by a known angle
α
(see figure at right). This
enables you to measure the basic rotation against any straight line
1
of the workpiece and to establish the reference to the actual 0°
direction
2
.
X
Y
Þ
1
2