8
Functions changed since the predecessor
versions 340 422-xx and 340 423-xx
The layouts of the status display and additional status display were
redesigned (see “Status Displays” on page 43).
Software 340 490 no longer supports the small resolution in
combination with the BC 120 screen (see “Visual display unit” on
page 37).
New key layout of the TE 530 B keyboard unit (see “Operating
panel” on page 39)
The entry range for the EULPR precession angle in the PLANE
EULER function was expanded (see “Defining the Machining Plane
with Euler Angles: EULER PLANE” on page 460).
The plane vector in the PLANE EULER function no longer has to be
entered in standardized form (see “Defining the Machining Plane
with Two Vectors: VECTOR PLANE” on page 462).
Positioning behavior of the CYCL CALL PAT function modified (see
“Calling a cycle in connection with point tables” on page 271)
The tool types available for selection in the tool table were increased
in preparation for future functions.