HEIDENHAIN TNC 620 (340 56x-02) Cycle programming User Manual
Page 334

334
Touch Probe Cycles: Automatic Datum Setting
15.7 D
A
TUM FR
OM OUTSIDE OF CIR
C
LE (Cy
c
le 413, DIN/ISO: G413)
U
New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the stud center. Default setting = 0. Input
range: -99999.9999 to 99999.9999
U
New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC should
set the stud center. Default setting = 0. Input range:
-99999.9999 to 99999.9999
U
Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 312).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).