10 datum circle center (cycle 416, din/iso: g416), Cycle run – HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual
Page 435

HEIDENHAIN TNC 640
435
16.1
0
D
A
TUM CIR
C
LE CENTER (Cy
c
le
416, DIN/ISO: G416)
16.10 DATUM CIRCLE CENTER
(Cycle 416, DIN/ISO: G416)
Cycle run
Touch Probe Cycle 416 finds the center of a bolt hole circle and
defines its center as datum. If desired, the TNC can also enter the
coordinates into a datum table or the preset table.
1
The TNC positions the touch probe at rapid traverse (value from
column FMAX) following the positioning logic (see "Executing touch
probe cycles" on page 373) to the center of the first hole
1
.
2
Then the probe moves to the entered measuring height and
probes four points to find the first hole center.
3
The touch probe returns to the clearance height and then to the
position entered as center of the second hole
2
.
4
The TNC moves the touch probe to the entered measuring height
and probes four points to find the second hole center.
5
The touch probe returns to the clearance height and then to the
position entered as center of the third hole
3
.
6
The TNC moves the touch probe to the entered measuring height
and probes four points to find the third hole center.
7
Finally the TNC returns the touch probe to the clearance height and
processes the determined datum depending on the cycle
parameters Q303 and Q305 (see "Saving the calculated datum" on
page 402) and saves the actual values in the Q parameters listed
below.
8
If desired, the TNC subsequently measures the datum in the touch
probe axis in a separate probing.
X
Y
1
2
3
Parameter number
Meaning
Q151
Actual value of center in reference axis
Q152
Actual value of center in minor axis
Q153