HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual

Page 522

Advertising
background image

522

Touch Probe Cycles: Automatic Kinematics Measurement

1

9

.4 MEA

S

URE KINEMA

TICS (Cy

c

le

451, DIN/ISO: G451; Option)

U

Feed rate for pre-positioning

Q253: Traversing

speed of the tool during positioning in mm/min. Input
range 0.0001 to 99999.9999; alternatively FMAX,
FAUTO

, PREDEF

U

Reference angle

Q380 (absolute): Reference angle

(basic rotation) for measuring the measuring points in
the active workpiece coordinate system. Defining a
reference angle can considerably enlarge the
measuring range of an axis. Input range 0 to 360.0000

U

Start angle A axis

Q411 (absolute): Starting angle in

the A axis at which the first measurement is to be
made. Input range -359.999 to 359.999

U

End angle A axis

Q412 (absolute): Ending angle in the

A axis at which the last measurement is to be made.
Input range -359.999 to 359.999

U

Angle of incid. A axis

Q413: Angle of incidence in

the A axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999

U

Number meas. points A axis

Q414: Number of probe

measurements with which the TNC is to measure the
A axis. If the input value = 0, the TNC does not
measure the respective axis. Input range 0 to 12

U

Start angle B axis

Q415 (absolute): Starting angle in

the B axis at which the first measurement is to be
made. Input range -359.999 to 359.999

U

End angle B axis

Q416 (absolute): Ending angle in the

B axis at which the last measurement is to be made.
Input range -359.999 to 359.999

U

Angle of incid. in B axis

Q417: Angle of incidence

in the B axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999

U

Number meas. points B axis

Q418: Number of probe

measurements with which the TNC is to measure the
B axis. If the input value = 0, the TNC does not
measure the respective axis. Input range 0 to 12

Advertising