8 burner jets, Model nga 2000 hfid, Instruction manual – Emerson Process Management 760004-A User Manual

Page 48

Advertising
background image

Instruction Manual

760004-A
February 2002

4-10 Maintenance and Service

Rosemount Analytical Inc. A Division of Emerson Process Management

Model NGA 2000 HFID

Air Baffle (Ref)
102260
See Below

Sample Jet
657005

Gasket
102256

Jet Assembly
657012

Gasket
102273

Nut, Jet
657016

Air Baffle

≈

.06

Position with tab over
the air hole
(approximately 1/16” to
the right).

End bent to raise it above the tab a
distance equal to the height of the tab.

7. Refer to Figure 4-8. Lift air baffle out

of burner base.

8. Remove the sample jet and gasket

from the bottom of the burner base.

9. Remove the jet nut. Grasp jet as-

sembly and lift out (along with upper
gasket) of burner base. Remove
bottom gasket.

Figure 4-8. Burner Jets

Advertising