7.2 Measurement Channels

If your inverter is equipped with a communication product, numerous measuring channels and
messages can be transmitted for diagnostics.

Measurement channel

Description

E-total

Total amount of energy fed in

Event-Cnt

Number of events that have occurred

Fac

Power frequency

Error

Identification of the present disturbance/error

h-on

Total operating hours

h-total

Total number of operating hours in feed-in operation

Iac

Grid current

Ipv

Direct current

Is

Apparent current

Power On

Total number of grid connections

Pac

Generated AC power

PF

Displacement power factor cos φ

Phase

The phase to which the inverter is connected.

Qac

Reactive power

Riso

Insulation resistance of the PV plant before connecting to the
power distribution grid.

Serial number

Inverter serial number

Status

Display of the current operating state

Vac

Grid voltage

Vpv

PV input voltage

Vpv-Setpoint

PV setpoint voltage