SMA STP 8000TL-10 User Manual
Page 25

SMA Solar Technology AG
5 Mounting
Installation Manual
STP8-17TL-IA-en-31
25
7. Screw the supplied eye bolt into the hole provided
in order to secure the enclosure from being
dislodged. The eye bolt only needs to be fastened
hand-tight.
8. In order to secure the enclosure on the rear panel,
fasten it at the bottom with the two M5x10
cheese-head screws supplied
(torque: max. 3.5 Nm).
9. Check to ensure that the inverter is securely in place.
☑ The inverter is now securely mounted to the wall.
If the inverter is not to be connected immediately, re-attach the lower enclosure lid:
– Dock the lower enclosure lid at an angle and
attach. The captive screws must protrude.
– Pre-fasten all six screws and then tighten them in
the sequence shown on the right
(torque: 2.0 Nm).