15 overload characteristics – Yaskawa Σ-III Series User Manual

Page 34

Advertising
background image

E-32

15 Overload Characteristics

The overload detection level is set under hot start* conditions at a servomotor surrounding air
temperature of 40

°C (104°F).

* A hot start indicates that both the SERVOPACK and the servomotor have

run long enough at the rated load to be thermally saturated.

Note: The overload protection characteristics of A, B, and C in the figure

are applicable when the SERVOPACK is combined with one of the
following servomotors.

Graph
Type

Motor Type

SGMAS

SGMPS

SGMSS

SGMCS

SGMMJ

SGMGH

A

-A5 to -04 -01 to -04

-02 to -35 -A1 to -A3

B

-06 to -12

-08 to -15

-10 to -30 -45 to -2Z

-03 to -30

C

-40 to -70

-40 to -75

10000.0

1000.0

100.0

10.0

1.0

Detecting time (s)

Maximum torque

Rated torque

(Maximum current)

(Rated current)

100%

Maximum torque

Rated torque

× 100%

A

B

C

Advertising