Stop spd gain p1-07= 0, Spindle ratio num p1-08= 1, Spindle ratio div p1-09= 1 – Yaskawa GPD515C-ZZZZ-CS104 User Manual
Page 8: For gpd 515/g5 adjustable frequency drives

Yaskawa Electric America Inc-www.drives.com
02Y00025-0526 Sheet 8 of 9
Date: 09/19/00
For GPD 515/G5
Adjustable Frequency Drives
Stop Spd Gain
P1-07= 0
P1-07
Stop Speed Gain
Q Q Q Q
Setting Range:
0 to 10
Factory Default:
0
This parameter sets the frequency threshold where the positioning algorithm takes control of stopping the drive. It is
based on a minimum threshold of 4.096 Hz with a 1 setting. The minimum threshold is multiplied by this value to achieve
a maximum threshold of 40.96 Hz. This value also controls the rate of deceleration. The positioning algorithm will bring
the drive to a stop in the orient position within 2 revolutions after initiated.
Spindle Ratio Num
P1-08= 1
P1-08
Spindle Ratio Numerator
Q Q Q Q
Setting Range:
1 to 10
Factory Default:
1
This parameter and P1-09 (Spindle Ratio Div) must be set to the proper spindle to motor ratio. This ratio is required for
the positioning to function properly.
Spindle Ratio Div
P1-09= 1
P1-09
Spindle Ratio Divisor
Q Q Q Q
Setting Range:
1 to 10
Factory Default:
1
This parameter and P1-08 (Spindle Ratio Num) must be set to the proper spindle to motor ratio. This ratio is required for
the positioning to function properly.