Auxiliary Analog Input Option Connector
AI-030
 
 
Frequency Reference Bias (n077 = 3)
Output Voltage Bias (n077 = 4)
 
 
 
 
The frequency reference bias (FBIAS) is 
added to the frequency reference. 
 
The reference is also manipulated by the 
internal frequency reference gain (n060 for 
terminal FR or n074 for terminal RP) and 
frequency reference bias (n061 for terminal 
FR or n075 for terminal RP). All 3 functions 
are used to calculate the final speed 
reference from terminals FR and RP. 
The output voltage bias (VBIAS) is added to 
voltage reference after the V/f pattern. This 
function should be used with caution as 
increasing or decreasing the motor voltage 
can cause excessive current draw, motor 
over-heating, motor stalling, etc.