the alphanumeric display. The XY

coordinate system used is as follows:

KEYPAD, FRONT VIEW

X =

0

1

2

3

4

|

|

|

|

|

Y = 0 —

00 10 20 30 40

1 —

01 11 21 31 41

2 —

02 12 22 32 42

3 —

03 13 23 33 43

PB1 ("NAME" push button) = 99

PB2 ("NEXT" push button) = 98

ERROR MESSAGES

When the RDU detects an error

condition, it shows an error message in the

alphanumeric display. The RDU reactions

and the error condition that caused the

reaction are as follows:

RDU REACTION

ERROR CONDITION

Shows “COMM.

35 seconds have

FAILURE” on alpha- elapsed since RDU

numeric display

has been updated

and blanks the

from RDC

numeric display

Shows “ - ” for the

Received invalid

number

numeric value

Bottom segment

Received invalid

of most significant

numeric value

digit is lit

Shows “ERR - WD

Watchdog timed out

TIMEOUT” and

halts

RDU REACTION

ERROR CONDITION

Shows “ERR - INT

Timer overflow inter-

TIMER” and halts

rupt occurred and

should not have

Shows “ERR - INT

A/D interrupt

A/D” and halts

occurred and should

not have

Shows “ERR - INT

HSI interrupt

HSI” and halts

occurred and should

not have

Shows “ERR - INT

HSO interrupt

HSO” and halts

occurred and should

not have

Shows “ERR - INT

HSI.0 interrupt

HSI.0” and halts

occurred and should

not have

Shows “ERR - INT

External interrupt

EXT” and halts

occurred and should

not have

RD 791-10

Advertising