3 New and Modified Software Functions
14
YASKAWA AMERICA, INC. TM.V1000SW.029 Traverse Application V1000 Custom Software Supplement
Figure 2
Figure 2 Master and Slave Output Diagram: Standard Operation
■
Implementation
Situation 1: Standard Operation
When programmed with the settings shown in
, the Traverse software produces
output waveforms similar to the ones in
. Using these settings and a reference
frequency of 45 Hz, the master drive operates based on the triangle waveform with 9 Hz
peak amplitude. Because the waveform is centered on the 45 Hz reference frequency, the
master waveform oscillates between 36 and 54 Hz while in Traverse mode.
Table 10 Sample Operating Parameters
Parameter
Name
Setting
P1-01
Disturbed P1-05 Waveform Selection
1
P1-02
Disturbed Waveform Amplitude
20.0%
P1-03
Disturbed Waveform Jump
50.0%
P1-04
Negative Slope Time
5.0 s
P1-05
Positive Slope Time
4.0 s
Run
command
Frequency
reference
0
U7-02
Slave Absolute
Frequency
U7-02
Slave Base Frequency
U7-03
Slave Ripple
Frequency
E1-04 x 50% (Hz)
Speed Agree
Disturb UP Status
multi-function output
During Disturbed
multi-function output
P1-02 x
Freq. Ref.
P1-02 x
Freq. Ref.
P1-02 x
Freq. Ref.
P1-02 x
Freq. Ref.
P1-02 x
Freq. Ref.
P1-02 x Freq. Ref. x P1-03
P1-02 x Freq. Ref. x P1-03
2 - P1-03
P1-02 x Freq. Ref. x P1-03
2 - P1-03
P1-02 x
Freq. Ref.
P1-04
P1-05