Top of Form Calibration

1. Press

Start.

2. You will now see a number for sensor output.
3. Insert paper until the sensor is above the white space.
4. Manually adjust the gain by pressing either Increase Gain or Decrease Gain until the sensor is below 45

for white space.

5. Insert the paper in more until the sensor is above the I-mark. Manually adjust the gain until the sensor

detects 180 or higher for the I-mark.

6. Press

Stop and Save.

Manual calibration


Calibrate TOF lets you calibrate the Top of Form. You can adjust the gain by pressing the Increase Gain or
Decrease Gain buttons. The target numbers are as follows:

Sensor Detects

Sensor Output Target

Whitespace

Less than 45

Top of Form

Greater than 180