38

31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi

Section 7 ·

Maintenance

7 Maintenance

!

DANGER

– Risk of fatal injury by electric shock at live

connections. Lethal voltages are still present in

the inverter and the connection box even after the

electrical connections have been disconnected.

– Wait five minutes before reaching into the

inverter and the connection box.

– When working on the photovoltaic modules, the

current must be switched off on the inverter and

the solar installation with the aid of the AC/DC

disconnect switch on the connection box.

ACTION

Switch off the line voltage and the solar generator with the
aid of the AC/DC disconnector (I = on or energized / O =
off or deenergized).

7.1 Cleaning the fan

If the fan is only covered with loose dust, it can be cleaned with
the help of a vacuum cleaner or a soft brush.

If the fan is very dirty, or if it s defective, it can be removed.

7.2 Removing the fan

If the fan is very dirty or defective, proceed as follows:

!

DANGER

Danger due to lethal voltages.

1.

Switch the DC/AC disconnect to the OFF (0) position to

de-energize the inverter and lock out to prevent inadvertent
energizing of the inverter during service.

2. Wait 5 minutes for the internal components of the
inverter to discharge.

3.

Remove the two inverter hinged door screws and open

door.

4.

Disconnect the fan connections

5HWXUQ 5HWXUQ

5HWXUQ

+RW

+RW

+RW

*1'

*1'

*1'