Module Configuration

The 250 Series module contains several registers that control its
configuration and operation. The module’s default settings allow it to
operate out of the box without any changes; however the registers allow
the link to be customized to better suit the application if necessary. The
register settings are stored in two types of memory inside the module.
Volatile memory is quick to access, but it is lost when power is removed
from the module. Non-volatile memory takes longer to access, but is
retained when power is removed.

All of the configuration settings have registers in both types of memory.
The settings are read from non-volatile registers on power up and saved in
volatile registers. The values in the volatile registers are used during normal
operation since it is faster to read and write the volatile memory locations.
There are commands to read and write both locations.

Figure 21 shows the volatile read-only registers. Figure 22 shows the
volatile read and write registers. Figure 23 shows the non-volatile read-only
registers. Figure 24 shows the non-volatile read and write registers.

Figure 21: 250 Series Volatile Read Only Configuration Registers

Figure 22: 250 Series Volatile Read / Write Configuration Registers

250 Series Volatile Read / Write Configuration Registers

Name

Address

Description

regCRCERRCOUNT

0x40

CRC error count value

regHOPTABLE

0x4B

Hop table

regPWRMODE

0x4D

Power amplifier setting

regUARTDATARATE

0x4E

UART data rate

regNETWORKMODE

0x4F

Sets the networking mode

regTXTO

0x50

UART to transmit timeout

regMAXTXRETRY

0x52

Maximum times to retry packet transmission

regUSECRC

0x53

Enable / Disable CRC checking

regUARTMTU

0x54

Minimum transmission unit

regCSMAMODE

0x56

Enable / Disable CSMA

250 Series Volatile Read-Only Configuration Registers

Name

Address

Description

regEXCEPTION

0x79

Stores latest exception code

regLGPRSSI

0x7B

Last Good Packet RSSI value

regIMMEDRSSI

0x7C

Current RSSI value

250 Series Volatile Read / Write Configuration Registers Continued

Name

Address

Description

regOPMODE

0x58

Sets operating mode

regACKONWAKE

0x59

Enable / Disable ACK sent to UART upon wake

regUSERDESTID[3]

0x5A

Destination Address for Extended User Networking

Mode

regUSERDESTID[2]

0x5B

Destination Address for Extended User Networking

Mode

regUSERDESTID[1]

0x5C

Destination Address for User and Extended User

Networking Mode

regUSERDESTID[0]

0x5D

Destination Address for User and Extended User

Networking Mode

regUSERSRCID[3]

0x5E

Source Address for Extended User Networking

Mode

regUSERSRCID[2]

0x5F

Source Address for Extended User Networking

Mode

regUSERSRCID[1]

0x60

Source Address for User and Extended User

Networking Mode

regUSERSRCID[0]

0x61

Source Address for User and Extended User

Networking Mode

regUSERIDMASK[3]

0x62

Address Mask for Extended User Networking Mode

regUSERIDMASK[2]

0x63

Address Mask for Extended User Networking Mode

regUSERIDMASK[1]

0x64

Address Mask for User and Extended User

Networking Mode

regUSERIDMASK[0]

0x65

Address Mask for User and Extended User

Networking Mode

regDESTGUID[3]

0x68

GUID Networking Mode Destination Address

regDESTGUID[2]

0x69

GUID Networking Mode Destination Address

regDESTGUID[1]

0x6A

GUID Networking Mode Destination Address

regDESTGUID[0]

0x6B

GUID Networking Mode Destination Address

regEXCEPTIONMASK

0x6C

Exception and Mask used to activate the EX line

regCMDHALT

0x6E

Half RF traffic when the CMD line is low

regLNAMODE

0x6F

Receiver LNA gain / linearity setting

regCOMPATMODE

0x70

Compatibility mode for 25 and 250

intercommunication

regAUTADD

0x71

Sets automatic addressing

Warning:

Modules that are not configured in the same way will not be

able to communicate reliably, causing poor performance or outright
failure of the wireless link. All modules in a network must have compatible
configurations to ensure interoperability.