Regusecrc, Reguartmtu, Regnvusecrc – Linx Technologies TRM-915-R250 User Manual

Page 24: Regnvuartmtu

Advertising
background image

– –

– –

42

43

UART Minimum Transmission Unit - Addr = 0x54; NV Addr = 0x09
This register determines the UART buffer level that triggers the transmission
of a packet. The minimum value is decimal 1 and the maximum value
is 192. The default value for this register is 64, which provides a good
mix of throughput and latency. At the maximum data rate, a value of
128 optimizes throughput. This register does not guarantee a particular
transmission unit size; rather, it specifies the minimum desired size. If there
is not enough time left in a hop, for instance, the protocol engine sends as
many characters as it can to fill the current hop, and sends the remaining
characters in the next hop. Figure 42 shows examples of the commands.

Figure 42: 250 Series UART MTU Command and Response

250 Series UART MTU

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x54

0x09

0x06

0x54

0x09

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x54

0x09

V1

CRC Control - Address = 0x53; NV Address = 0x08
The 250 Series protocol includes a Cyclic Redundancy Check on the
received packets to make sure that there are no errors. Any packets
with errors are discarded and not output on the UART. This feature can
be disabled if it is desired to perform error checking outside the module.
Set the regUSECRC register to 0x01 to enable CRC checking, or 0x00
to disable it. The default CRC mode setting is enabled. Figure 40 shows
examples of the commands and Figure 41 shows the available values.

250 Series CRC Control Register Settings

V1

Mode

0x00

CRC Disabled

0x01

CRC Enabled

Figure 40: 250 Series CRC Control Command and Response

Figure 41: 250 Series CRC Control Register Settings

250 Series CRC Control

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x53

0x08

0x06

0x53

0x08

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x53

0x08

V1