Regopmode, Regackonwake, Regnvopmode – Linx Technologies TRM-915-R250 User Manual

Page 26: Regnvackonwake

Advertising
background image

– –

– –

46

47

ACK on Wake - Address = 0x59; NV Address = 0x0E
When the module powers up and is ready for operation, it can output an
acknowledge (ACK) character (0x06) on the TXD line. This indicates that
the module is ready to accept data and commands. Setting this register to
0x00 disables the ACK, 0x01 enables the ACK. The default value is 0x01.
Figure 49 shows examples of the commands and Figure 50 shows the
available values.

Figure 49: 250 Series ACK on Wake Command and Response

250 Series ACK on Wake Register Settings

V1

Mode

0x00

Disable ACK

0x01

Enable ACK

Figure 50: 250 Series ACK on Wake Register Settings

250 Series ACK on Wake

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x59

0x0E

0x06

0x59

0x0E

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x59

0x0E

V1

Operating Mode - Address = 0x58; NV Address = 0x0D
The value in the regOPMODE register sets the operating mode of the
transceiver. If the module remains properly powered, and is awakened from
a low power mode properly, the volatile registers retain their values when
awakened. If the volatile registers become corrupted during low power, a
software reset is forced and the module reboots.

Awake mode is the normal operating mode. This is the only mode in which
the RF circuitry is able to receive and transmit RF messages.

Standby leaves the RF oscillator circuit operating for faster wakeup,
whereas Sleep does not. One byte of 0x0F to the module’s RXD line at the
current baud rate wakes the modules.

Deep Sleep mode disables all circuitry on-board the module. This is the
lowest-power mode available for the module. A low pulse on the RESET
line of at least 15µs wakes the module. The module begins the wake
process once the RESET line is returned high.

Please see the Low Power States section for more details. Figure 47 shows
examples of the commands and Figure 48 shows the available values.

Figure 47: 250 Series Operating Mode Command and Response

250 Series Operating Mode Register Settings

V1

Mode

0x00

Awake Mode

0x01

Sleep Mode

0x02

Standby Mode

0x03

Deep Sleep Mode

Figure 48: 250 Series Operating Mode Register Settings

250 Series Operating Mode

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x58

0x0D

0x06

0x58

0x0D

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x58

0x0D

V1

Advertising
This manual is related to the following products: