Resources, Reflow oven: +240°c max (see figure 36) – Linx Technologies RXM-GPS-R4 User Manual
Page 18
 
–
–
–
–
30
31
Resources
Support
For technical support, product documentation, application notes, regulatory 
guidelines and software updates, visit www.linxtechnologies.com
RF Design Services
For customers who need help implementing Linx modules, Linx offers 
design services including board layout assistance, programming, 
certification advice and packaging design. For more complex RF solutions, 
Apex Wireless, a division of Linx Technologies, creates optimized designs 
with RF components and firmware selected for the customer’s application. 
Call +1 800 736 6677 (+1 541 471 6256 if outside the United States) for 
more information.
Antenna Factor Antennas
Linx’s Antenna Factor division has the 
industry’s broadest selection of antennas 
for a wide variety of applications. For 
customers with specialized needs, custom 
antennas and design services are available 
along with simulations of antenna performance to speed development. 
Learn more at www.linxtechnologies.com.
by
Reflow Temperature Profile
The single most critical stage in the automated assembly process is the 
reflow stage. The reflow profile in Figure 36 should not be exceeded 
because excessive temperatures or transport times during reflow will 
irreparably damage the modules. Assembly personnel need to pay careful 
attention to the oven’s profile to ensure that it meets the requirements 
necessary to successfully reflow all components while still remaining 
within the limits mandated by the modules. The figure below shows the 
recommended reflow oven profile for the modules.
Shock During Reflow Transport
Since some internal module components may reflow along with the 
components placed on the board being assembled, it is imperative that 
the modules not be subjected to shock or vibration during the time solder 
is liquid. Should a shock be applied, some internal components could be 
lifted from their pads, causing the module to not function properly.
Washability
The modules are wash-resistant, but are not hermetically sealed. Linx 
recommends wash-free manufacturing; however, the modules can be 
subjected to a wash cycle provided that a drying time is allowed prior 
to applying electrical power to the modules. The drying time should be 
sufficient to allow any moisture that may have migrated into the module 
to evaporate, thus eliminating the potential for shorting damage during 
power-up or testing. If the wash contains contaminants, the performance 
may be adversely affected, even after drying.
Preheat:
150 - 200°C
Peak: 240+0/-5°C
25 - 35sec
220°C
2 - 4°C/sec
120 - 150sec
2 - 3°C/sec
60 - 80sec
30°C
Figure 36: Maximum Reflow Temperature Profile