Maintenance

Maintenance

Note: Determine the left and right sides of the machine from the normal operating position.

WARNING

While maintenance or adjustments are being
made, someone could start the engine.
Accidental starting of the engine could
seriously injure you or other bystanders.

Remove the key from the ignition switch,
engage parking brake, and pull the wire(s)
off the spark plug(s) before you do any
maintenance. Also push the wire(s) aside
so it does not accidentally contact the spark
plug(s).

WARNING

The engine can become very hot. Touching
a hot engine can cause severe burns.

Allow the engine to cool completely before
service or making repairs around the engine
area.

Recommended Maintenance Schedule(s)

Maintenance Service

Interval

Maintenance Procedure

Before each use or daily

• Check the blower housing/impeller.
• Check door cloth mesh.
• Check exhaust diverter.
• Clean muffler and rear frame area.
• Clean rear screen in the hopper.

Every 25 hours

• Lubricate grease fittings.

Every 50 hours

• Check condition of belt.

Yearly or before storage

• Clean blower.

Periodic Maintenance

Check Blower
Housing/Impeller

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Inspect for wear or damage daily. Replace or

repair worn parts as needed

Note: When mowing in areas with sandy soil,
use low lift blades on the cutting deck and higher
cutting heights to minimize wear on the blower
components.

Check Door Cloth Mesh

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove key. Engage parking brake.

2. Inspect the door cloth mesh for wear, tears, or

damage.