Ethernet interface configuration screen, Figure 6-3, Screen example – Enterasys Networks 6H2xx User Manual

Page 169: Field descriptions, Figure 6-3 ethernet interface configuration screen

Advertising
background image

Ethernet Interface Configuration Screen

Port Configuration Menu Screens

6-5

Screen Example

Figure 6-3

Ethernet Interface Configuration Screen

Field Descriptions

Refer to

Table 6-2

for a functional description of each screen field.

Table 6-2

Ethernet Interface Configuration Screen Field Descriptions

Use this field…

To…

Intf
(Read-Only)

See the interface number.

Port
(Read-Only)

See the number of the physical port on the interface. For the front panel
ports on the switch module, this will always be 1.

PortType
(Read-Only)

See the type of interface using the name of the physical port type. For
the Ethernet 10/100 Mbps ports in the switch module, FE-100TX will
be displayed. If a Fast Ethernet port is installed via an optional HSIM,
the interface displayed may be FE-100TX or FE100-FX. If a Gigabit
port is installed via an optional VHSIM, the interface displayed may be
GE-1000SX, GE-1000LX, or GE-1000CX.

25041-92w

RETURN

EXIT

NEXT

Intf

1

2

3

4

5

6

7

8

9

10

11

12

Port

1

1

1

1

1

1

1

1

1

1

1

1

PortType

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

FE-100TX

Link

No Link

No Link

No Link

No Link

Link

No Link

No Link

Link

Link

Link

Link

Link

Speed

100

10

100

10

10

100

100

100

100

100

100

100

Duplex

Full

Half

Full

Half

Full

Full

Full

Half

Full

Full

Full

Full

Config

Manual

AutoNeg

AutoNeg

AutoNeg

AutoNeg

Manual

Manual

AutoNeg

AutoNeg

AutoNeg

AutoNeg

AutoNeg

FDX FC

Off

Sym

Sym

Off

Sym

Off

Off

Off

Off

Off

Off

Off

HDX FC

On

Off

Off

On

On

On

On

On

On

On

On

On

Advertising