Remote Operation, cont’d

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation

4-6

PRELIMINAR

Y

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

RGB mute commands

RGB mute

X@

*1B

Vmt

X@

*1

]

Mute output

X@

RGB (video

off).

RGB unmute

X@

*0B

Vmt

X@

*0

]

Unmute output

X@

RGB

(video on).

Read RGB mute

X@

B

X#]

1 = mute on, 0 = mute off.

Global RGB mute

1*B

Vmt1

]

Mute all RGB outputs.

Global RGB unmute

0*B

Vmt0

]

Unmute all RGB outputs.

N

An IR 501 user can mute video and/or audio with a string of IR commands that cannot be duplicated by a computer or

control system sending SIS commands. The switcher sends the following responses:

IR 501 RGB and audio mute

{none}

Mut

X@

*1

]

Output

X@

’s RGB and audio

are muted.

IR 501 RGB mute

{none}

Vmt

X@

*1

]

Output

X@

’s RGB is muted.

IR 501 RGB and audio
unmute

{none}

Zpz

]

Output

X@

’s RGB and audio

are unmuted.

Audio input gain and attenuation

N

The set gain (G) and set attenuation (g) commands are case sensitive.

Set audio input gain to +dB
value

X$

*

X%

G

In

X$

•Aud

X^]

Example:

1*2G

In1•Aud+02

]

Set input 1 audio gain to +2 dB.

Set audio input attenuation
to -dB value

X$

*

X&

g

In

X$

•Aud

X^]

Increment gain

X$

+G

In

X$

•Aud

X^]

Increase gain by 1 dB.

Example:

5+G

In5•Aud+03

]

Increase audio input 5 level
from +2 dB to +3 dB.

Decrement gain

X$

-G

In

X$

•Aud

X^]

Decrease gain by 1 dB.

Example:

7-G

In7•Aud-09

]

Decrease audio input 7 level
from -8 dB to -9 dB.

Read input gain

X$

G

X^]

Example:

3G

-06

]

Audio input 3 level is at -6 dB.

Audio output level

Set audio output to the
consumer level (-10 dBV)

X@

*0*40#

Out

X@

•Lvl0

]

Set output

X@

level to

consumer (-10 dBV).

Set audio output to the
proffesional level (+4 dBu)

X@

*1*40#

Out

X@

•Lvl1

]

Set output

X@

level to

pro (+4 dBu) (default).

Read output level

X@

+40#

X*]

Example:

3*40#

1

]

Output 3 audio level is pro
(+4 dBu).

N

X@

= Output number

1 – (maximum number of outputs for your model)

X#

= Mute

1 = on (muted)

0 = off (unmuted)

X$

= Input number

1 – (maximum number of inputs for your model)

X%

= Audio gain

0 – 24 (1 dB/step)

X^

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X&

= Audio attenuation

1 – 18 (1 dB/step)

X*

= Output gain

0 = consumer level (–10 dBV)

1 = professional level (+4 dBu)

Advertising