SUPREMA 2001 - OPERATION & SERVICE MANUAL

Page 16 of 60

July 6, 2001

Suprema 2001 - Operation & Service

SET-UP MODE & ACCESS CODE

After scrolling past all of the counters, an access code is required to get into the "

SET

-

UP

" section of the software. This section allows changes to be made to the computer

programming. The procedures are outlined below.


1. Enter the factory pre-set access code.

a) Factory pre-set access code - press the following in the sequence outlined

below;

1 COFFEE
2 50/50
3 DECAF
4 HOT

WATER

b) The message on the display will now read,

2. The "

SET

-

UP

" mode has now been accessed, and changes can be made.

a) The following is the sequence of the settings that appear when you scroll

through the "

SET

-

UP

" mode. Please note that there are some differences

between the Regular software version and the APP software version.

Suprema Model Type

REG APP

PRODUCT ON/OFF

●

SET PRODUCT

●

●

SET WATER

●

●

SET PRICE

●

●

ENABLE SWITCHES

●

●

SET DEFAULT

●

●

SET TOP PAUSE

●

●

SET BOTTOM PAUSE

●

●

MAXIMUM CUPS FOR CARAFE

●

●

FREQUENCY OF MESSAGES

●

SERVICE COUNTER

●

BOTTOM PAUSE DELAY

●

●

MESSAGES ON / OFF

●

●

FREE VEND KEY SWITCH

●

●

SET GROUNDS CONT.

●

CHOCO PUMP CYCLES

●

●

DOUBLE-CUP SET-UP

●

●

SET TEMPERATURE

●

●

CUSTOM MESSAGES

●

LANGUAGE

●

SET WATER LEVEL

●

●

SET POWDER MIX

●

SET POWDER BEV.

●

WATER MAX. BREWER

●

LOCK COUNTERS

●

FORCE VEND

●

●

●

Available Feature

PRODUCT ON/OFF

PRESS <START>

$

Tip:

To bypass the
counters and go
directly to the
access code menu,
press the hidden
“

DOWN” menu

scroll button, after
pressing the “

SET

-

UP

” button.