Emerson P/N 400361-00 User Manual

Page 132

Advertising
background image

118 www.emersonct.com SM-EZMotion Module User Guide

104

Y

Following Error

Amount of following error exceeded
following error limit set in PowerTools
Pro software.

Increase Following Error Limit in
PowerTools Pro configuration. Increase
Velocity Loop Bandwidth and/or Position
Loop Bandwidth in PowerTools Pro
configuration. Lower Acceleration/
Deceleration ramp values. Make sure that
programmed velocity is within maximum
operating speed of the given motor.

105

N

Travel Limit Plus

Hardware Travel Limit Plus switch has
activated, or Software Travel Limit
Plus position has been exceeded

Verify motion profiles/programs to make
sure that motion is not configured to
exceed desired travel positions

106

N

Travel Limit Minus

Hardware Travel Limit Minus switch
has activated, or Software Travel Limit
Minus position has been exceeded

Verify motion profiles/programs to make
sure that motion is not configured to
exceed desired travel positions

107

Y

No Program Error

SM-EZMotion module has no
configuration loaded in it

Download a configuration to the
SM-EZMotion module using PowerTools
Pro software

108

Y

Motion Trajectory Error

Maximum allowable position change
within one control loop update has
been exceeded

If using the "Using Capture.#" instruction
after an Index.#.Initiate instruction in your
user program, make sure that the
captured data is recent enough so that
the motor can actually achieve the
necessary acceleration

109

Y

Trajectory Update Overrun Error

Control Loop processing time has
taken longer than the user selected
Trajectory Update Rate

Select a longer Trajectory Update Rate in
the PowerTools Pro configuration. A
longer Trajectory Update Rate gives the
control loop more time to process. Be
sure not to enable any PLS's, Captures,
or Queues that are not being used.

120

Y

File Corruption Error - Consult Factory

121

Y

File Corruption Error - Consult Factory

122

Y

File Corruption Error - Consult Factory

123

Y

Program Error - Buffer Overrun

124

Y

Program Error - Call Stack Overflow

Too many "Call Program" instructions
have been processed without
returning to original "calling" program

Do not nest more than four "Call
Program" operations. To avoid this, return
to the original calling programs before
calling another program. (See Call
Program instruction explanation in this
manual for more information).

125

Y

File Corruption Error - Consult Factory

126

Y

File Corruption Error - Consult Factory

127

Y

Flash Error

Loading from Flash Memory has failed

Re-download original PowerTools Pro
configuration file. If problem persists,
please contact factory.

128

Y

File Corruption Error - Consult Factory

129

Y

Program Error - Illegal Command

User Program has processed an
illegal command

Re-download original PowerTools Pro
configuration file. If problem persists,
please contact factory.

130

Y

File Corruption Error - Consult Factory

131

Y

File Corruption Error - Consult Factory

132

Y

File Corruption Error - Consult Factory

133

Y

File Corruption Error - Consult Factory

134

Y

File Corruption Error - Consult Factory

Error Code

(x.50)

Cause

Trip?

Error

Possible Reason

Possible Solution

Advertising