Casio ClassPad II fx-CP400 User Manual
Page 211

Chapter 12: Program Application
211
Chapter 12: Program Application
211
RclVWin
Misc - Graph&Table(2)
Syntax: RclVWin
Ⅺ{<variable name> ; <folder name\
file name>}
Function: Recalls View Window values, which were
previously saved under the specified name.
Description: A folder path can be specified only up to
one level.
Receive38k
I/O - Communication
Syntax: Receive38k
Ⅺ<variable name>
Function: Receives EA-200 data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Receive command in the examples provided in
the EA-200 user documentation with the command
Receive38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
Rename
Misc - Variable
Syntax: Rename
Ⅺ<current variable name>, <new
variable name>
Function: Renames a variable.
Return
Ctrl - Control
Syntax: Return
Ⅺ{<variable>}
Function 1 (Main Program): Terminates program
execution.
Function 2 (Subroutine Program): Returns from a
subroutine.
Tip
• The Return command can be executed during an If, For,
Do, While, or Switch process.
• Appending a <variable> to the Return command in
the Main application and executing the command will
cause the variable to be displayed when the program is
complete.
S
Scatter
Misc - Statistics(1) - Graph
Function: Used as a StatGraph command argument
to specify an option. See StatGraph.
Send38k
I/O - Communication
Syntax: Send38k
Ⅺ<variable name>
Function: Sends EA-200 data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Send command in the examples provided in the
EA-200 user documentation with the command
Send38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
• <variable name> must be a variable that contains
a real number or a list. Anything else results in an
error.
SendVar38k
I/O - Communication
Syntax: SendVar38k
Ⅺ<variable name>
Function: Sends variable names and variable
contents.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
SeqSelOff
Misc - Sequence
Syntax: SeqSelOff
Ⅺ{
a
n
+1
;
a
n
+2
;
b
n
+1
;
b
n
+2
;
c
n
+1
;
c
n
+2
;
a
n
E ;
b
n
E ;
c
n
E}
Function: Deselects the specified sequence
expression. Specifying “
a
n
E”, “
b
n
E”, or “
c
n
E” as the
argument activates [Explicit]. Specifying any other
argument activates [Recursive].
SeqSelOn
Misc - Sequence
Syntax: SeqSelOn
Ⅺ{
a
n
+1
;
a
n
+2
;
b
n
+1
;
b
n
+2
;
c
n
+1
;
c
n
+2
;
a
n
E ;
b
n
E ;
c
n
E}
Function: Selects the specified sequence expression.
Specifying “
a
n
E”, “
b
n
E”, or “
c
n
E” as the argument
activates [Explicit]. Specifying any other argument
activates [Recursive].
SeqType
Misc - Sequence
Syntax: SeqType
Ⅺ{"
n
" ; "
a
n
+1
a
0
" ; "
a
n
+1
a
1
" ; "
a
n
+2
a
0
" ;
"
a
n
+2
a
1
"}
Function: Specifies the recursion type.
Description: Specifying “
n
” as the argument activates
[Explicit]. Specifying any other argument activates
[Recursive].