Model IFT9701 Transmitter Instruction Manual

65

HA

R

T

Me

n

u

T

re

e

s

Retu

rn
P

o

li

c

y

Op
tio
n

al Di

sp
la

y

Spec

ifications

Appendix A

IFT9701 Specifications

A.1

Performance specifications

For performance specifications, refer to the documentation for your sensor.

A.2

Functional specifications

A.2.1

Output signals

Milliamp (active)

•

4–20 mA output represents mass flow or volume flow

•

Sensor size determines minimum and maximum spans. Recommended minimum span (% of
nominal flow range):

-

ELITE sensors: 2.5%

-

F-Series sensors: 10%

-

D and DL sensors: 10%

•

Load limit is 600 ohms

•

Internally powered (active)

•

Isolated to ±500 VDC from all other outputs and earth ground

•

Out-of-range capability is 3.8 or 20.5 mA

Pulse (passive)

•

Pulse output represents mass or volume flow

•

Externally powered (passive), requires pull-up resistor to 5–30 VDC power supply

•

Minimum resistance is 500 ohms at 5 V, 3 kohms at 30 V

•

Galvanically isolated to ±500 VDC

•

Out-of-range capability to 7200 Hz

•

Voltage in on state is less than 1 V

•

Below 1 Hz, the pulse width will be 500 ms; at all pulse frequencies between 1 Hz and
7200 Hz, the pulse width is half the pulse period

Communication

•

HART protocol-compatible Bell 202 digital signal is superimposed on 4–20 mA analog signal,
and available for host system interface

•

Frequency 1.2 and 2.2 kHz, amplitude 0.5 mA peak-to-peak, baud rate 1200 baud

•

Requires 250 to 600 ohms load resistance