Z8 Encore!

®

Flash Microcontroller Development Kit

User Manual

25

UM014605-0208

Z8 Encore!® Evaluation Board

If the IrDA board is installed the Console port is disabled.

Table 10. J7 External Vref

Shunt Status Function

Device or Register Affected

IN

External Vref is used for ADC

Internal Vref is disabled.

OUT

Internal Vref is used for ADC

Internal Vref is enabled.

Table 11. J9 Vref

Function

Device or Register Affected

J9-1

Test point to external Vref

Vref

J9-2

GND

None

Table 12. J10 IrDA Enable/Disable

Shunt Status

Function

Device Affected

IN

IrDA enabled

Only the IrDA interface is operational.

OUT

IrDA disabled

UART0 communicates through RS-232.
If J6 12-14 is IN Port A (3-5) can be
assigned to other functions (console
connector P1 is disabled).
If J6 12-14 is OUT console connector P1
is enabled (Port A (3-5) is assigned to
UART0).