Powxq5350 – Powerplus POWXQ5350 MITRE SAW +UPPER TABLE 1800W 305MM EN User Manual

Page 18

Advertising
background image

POWXQ5350

EN

Copyright © 2014 VARO

P a g e

| 18

www.varo.com

 Clean the surfaces of the following components:

o

The saw shaft

o

The inner saw flange

o

The saw blade

o

The outer saw flange

o

Adapter ring

o

The saw blade guard

HAZARD! Do not use any cleaning products (for instance for removing
resin residues) that have the tendency to cause corrosion on light metals;
this could damage the machine.

 Put the inner saw flange and the adapter ring on the saw shaft.

HAZARD! Be sure to fasten the inner saw flange correctly! The saw may
block, or the saw blade may come lose, if the flange is not correctly
fastened.

 Mount the new saw blade and check the rotating direction (the arrow on the saw blade

must point in the same direction as the arrow on the saw blade guard!).

HAZARD! Only use saw blades that conform to the applicable standards
and that can be used at the maximum speed indicated in the technical data
sheet.

 DO NOT use:

o

Wrong saw blades

o

Saw blades made of high-speed steel (HSS)

o

Damaged saw blades

o

Saw blades with missing teeth

HAZARD!

 Only use OEM components for installing the saw blade.

o

Do not use loose reduction rings; the saw blade could come loose.

o

Saw blades must be mounted in such a way that they cannot wobble, and that they
cannot come loose during operations.

 Install the outer saw flange.
 The two flanges must fit over the surfaces of the saw shaft.
 Insert the shaft bolt (left-turning thread) and tighten with a hexagonal spanner.

HAZARD!

 Do not lengthen the spanner, so that you can exercise more power.
 Do not hit on the spanner with a hammer, for tightening the shaft.
 The spanner must be removed, after the shaft that has been tightened.
 Install the saw table and mount the corresponding screws.