Setting up serial communication, Connector pin assignments, Connector pin assignments – Extron electronic Multi-Graphic Processor MGP 464 DI User Manual
Page 54: Preliminar y, Software configuration and control

MGP 464 • Software Configuration and Control
4-2
Software Configuration and Control
PRELIMINAR
Y
The MGP 464 can be configured and controlled by software via the following
interfaces:
RS-232 or RS-422 (Simple Instruction Set [SIS
•
™
] commands or Windows
®
-
based control software)
LAN (Web pages, SIS commands, or Windows-based control software)
•
This chapter discusses the use of the SIS commands and how to access the
Windows-based control software. For instructions on using the Windows-based
control software, refer to the software's Help program. See chapter 5, "HTML
Configuration and Control," for information on using the Web pages.
Setting Up Serial Communication
The MGP 464 has two serial communication ports: the RS-232/422 port, accessed
via a 9-pin female D-sub connector on the rear panel, and the Config port, a 2.5 mm
TRS connector on the front panel. These ports are used to connect to a host or
external controlling device, such as a computer or control system, which can
generate the proper command codes and recognize the processor’s responses.
Connector pin assignments
The 9-pin RS-232/422 connector on the rear panel (see the
illustration at right) has the following pin assignments:
The 2.5 mm TRS RS-232 connector on the front panel may be connected to a
computer via the optional 9-pin D to 2.5 mm stereo mini TRS RS-232 cable
(part #70-335-01). The pin assignments are shown below.
6 feet
(1.8 m)
Part #70-335-01
9DBF-2.5mm TRS cable_031504.eps
5
1
9
6
Sleeve (Gnd)
Ring
Tip
9-pin D
Connection
TRS Plug
Pin 2
Computer's RX line
Tip
Pin 3
Computer's TX line
Ring
Pin 5
Computer's signal ground
Sleeve
Front panel RS-232 configuration port pin assignments
Pin RS-422 function Description
1
–
No connection
2
Tx-
Transmit ground
3
Rx-
Receive ground
4
–
No connection
5
Gnd
Signal ground
6
–
No connection
7
Rx+
Receive data
8
Tx+
Transmit data
9
–
No connection
Pin RS-232 function
Description
1
–
No connection
2
Tx
Transmit data
3
Rx
Receive data
4
–
No connection
5
Gnd
Signal ground
6
–
No connection
7
–
No connection
8
–
No connection
9
–
No connection
5
1
9
6