Trouble-shooting

Problem

Possible cause(s)

To correct the fault

Pump does not

start

No power supply

Check socket, cable lead and plug, if

necessary have a repair carried out

by an electrician

Float switch ( 5) does not

operate

Check the position of the float switch

Water level inadequate when

starting

Submerge the pump deeper

Thermal protection switch

has tripped

Wait until motor cools down and

switches on again. Unplug appliance

and clean suction foot/impeller wheel.

Pump is running,

but not pumping

water

Suction foot ( 8) /

filter ( 7) blocked

Clean suction foot / filter

Pressure lead closed

Open the distributor shut-off tap,

other tap or jet, etc.

Pumping capacity affected by

extreme dirt or abrasive sol-

ids mixed with the water

Withdraw the power plug and clean

the pump, if necessary replacing

worn parts.

Pump does not

switch off

Float switch ( 5) cannot

sink

Check position of the float switch

Amount pumped

is inadequate

Suction foot ( 8) /

filter ( 7) blocked

Clean suction foot / filter

Pumping capacity affected by

extreme dirt or abrasive sol-

ids mixed with the water

Withdraw the power plug and clean

the pump, if necessary replacing

worn parts (see “Cleaning, mainte-

nance and storage”).

If necessary, operated the pump

without the distribution piece.

Pump switches

off after only run-

ning a short time

Motor protection switches off

the pump because of exces-

sively dirty water.

Withdraw the power plug and clean it.

Water temperature is too

high, Motor protection switch-

es the appliance off.

Maximum permitted water tempera-

ture of 35°C must be observed!

Spare parts

When you wish to purchase spare parts, please contact our service address or the fax

number given.