17. Troubleshooting guide

Motor not running

Cause

Remedy

- Power supply not connected

- Impeller blocked, thermostat has swit-

ched off

- Check voltage supply

- Take pump apart and clean it

Pump not priming

Cause

Remedy

- Intake valve not in the water

- No water in the pump chamber

- Air in the intake line

- Intake valve leaking

- Intake cage (intake valve) blocked

- Max. intake height exceeded

- Place intake valve in water

- Fill pump housing with water

- Check sealing of intake line

- Clean intake valve

- Clean intake cage

- Check intake height

Insufficient pumping rate

Cause

Remedy

- Intake height too high

- Intake cage soiled

- Water level falling rapidly

- Pump performance reduced by foreign

bodies (sand, stones, etc.)

- Check intake height

- Clean intake cage

- Place intake valve lower down

- Clean pump and replace wearing parts

Thermostat switches off the pump

Cause

Remedy

- Motor overloaded, excessive friction

caused by foreign bodies

- Dismantle and clean pump, prevent in-

take of foreign bodies (filter)

Caution! The pump must not run dry.

Anleitung_LB6_4171185.indb 11