5. Technical data

Mains connection: .................. 230V ~ 50 Hz

Power rating: ....................................1000 W

Max. delivery rate ............................4600 l/h

Max. delivery head ...............................45 m

Max. delivery pressure ... 4.5 bar (0.45 MPa)

Max. suction height ................................7 m

Pressure and suction connector: ..................

............approx. 33.3 mm (R1 female thread)

Max. water temperature .......................35°C

Sound pressure level L

pA

..........72.03 dB (A)

Uncertainty K

pA

...............................3 dB (A)

Peak noise level:

Measured .................................84.62 dB (A)

Uncertainty K

WA

...............................3 dB (A)

Guaranteed ...................................86 dB (A)

Protection class ..........................................I

Protection type ..................................... IPX4

Weight................................................8.9 kg

6. Operating instructions

As a basic principle, we recommend the

use of a preliminary filter and a suction set

with suction hose, intake cage and non-

return valve, in order to prevent long priming

periods and unnecessary damage to the

pump as a result of stones and solid foreign

bodies.

7. Fitting the carry handle

Fasten the carry handle with the 2

screws supplied (see Fig. 2).

8. Mains connection

The mains connection needs a 230 V ~

50 Hz shock-proof socket. Minimum 10-

amp fuse required. Please ensure that

the power socket is easily accessible.

Switch on/off at the built-in switch (see

Fig. 1/Item 2).

The motor is protected from overload

or blockage by a built-in temperature

monitor. In case of overheating the tem-

perature monitor automatically switches

the pump off. After the equipment has

cooled down, the pump will switch on

again automatically.

9. Fitting a suction pipe

Screw the suction pipe (min. 19 mm

(3/4“) plastic pipe with spiral reinforce-

ment) approx. 33 mm onto the intake

line connection (R1 female thread) of

the pump (Fig. 1/Item 5) either directly or

with the aid of a threaded nipple.

The suction hose should have an intake

valve. If the intake valve cannot be used

then a non-return valve should be ins-

talled in the intake line.

Position the intake line so that it rises

from the water withdrawal point to the

pump. Avoid positioning the intake line

higher than the pump as this would

delay the escape of air bubbles from

the intake line and impede the priming

process.

Install the intake and discharge lines in

such a way that they do not exert any

mechanical pressure on the pump.

The intake valve should be low enough

in the water to ensure that the pump will

not run dry if the water level falls.

A leaking intake line will draw in air and

therefore not draw in any water.

Take measures to prevent the intake of

foreign bodies (sand, etc.). If necessary

install a coarse filter.