Putting into service – Florabest FRP 350 C2 User Manual

Page 44

Advertising
background image

44

GB

Electrical safety:

Caution: to avoid accidents and

injuries from electric shocks:

• The equipment is not to be operated if

there are people in the water. There is

a risk of electric shock.

• After erection, the mains plug must be

freely accessible when the equipment is

in operation.

• Before operating your new pump, have

a specialist check:

- The earthing, the protective multiple

earthing; the residual current circuit

breaking must be compliant with the

safety regulations of the energy supply

company and function without fault,

- The protection of the electrical plug

connections from the wet.

- If there is a risk of flooding, fix the

plug connections in an area that is

safe from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connect the equipment only to a socket

with a residual current protection de-

vice (residual current circuit breaker)

with a rated current of not more than

30 mA; minimum fuse 6 amperes.

• Before each use, check the equipment,

cable and plug for damage. Defec-

tive cables are not to be repaired, but

rather replaced by new ones. Have

damage on your equipment repaired

by an authorised specialist.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll a

cable drum before use. Check the ca-

ble for damage.

• Disconnect the mains plug from the sock-

et before all work on the equipment, in

case of leaks in the water system, during

work breaks, and when not in use.

• The cross-section of mains connection

lines must be no smaller than rubber

hose lines with the designation H07RN-F.

The line must be 10 m long.

The flexible lead cross-section of the ex-

tension cord must at least 2.5 mm

2

.

• Protect cables and electrical connections

against moisture. Make sure that cables

and electrical connections are located in

areas safe from flooding.

Putting into service

Assembling instructions

Before installing the aluminium

tubes and the flexible tube, check

that a sealing ring has been in-

serted in each screw socket. If not,

insert the sealing ring in the follow-

ing manner:

Inserting the sealing rings:

1. Press:

- One small sealing ring (23) into

each of the threaded sleeves

in the three aluminium tubes.

(13/14/15),

- One large sealing ring (21)

into the threaded sleeve on the

flexible tube (20).

Advertising